Overview
The 107 is a rugged, accurate probe that measures temperature of air, soil, or water from -35° to +50°C. It easily interfaces with most Campbell Scientific data loggers and can be used in a variety of applications. The 107 consists of a thermistor encapsulated in an epoxy-filled aluminum housing. The housing protects the thermistor, allowing you to bury the probe in soil or submerge it in water.
Key Advantages
Can be used in a variety of applications
Technical Description
| Specification | Value |
|---|---|
| Sensor | BetaTherm 100K6A1IA thermistor |
| Tolerance | ±0.2°C from 0°C to 50°C |
| Measurement temperature range | −35°C to +50°C |
| Survival temperature range | −50°C to +100°C |
| Steinhart–Hart equation error | ≤±0.01°C across the measurement range; applies to CRBasic data loggers |
| Polynomial linearization error | Typically <±0.5°C across the measurement range; applies to Edlog data loggers |
| Air response time constant | 30–60 seconds at a wind speed of 5 m/s |
| Maximum submergence depth | 15 m (50 ft) |
| Probe diameter | 0.76 cm (0.3 in.) |
| Probe length | 10.4 cm (4.1 in.) |
| Maximum cable length | 305 m (1,000 ft) typically needs no programming adjustment. Runs up to 762 m (2,500 ft) require programming adjustments; see Section 8.4 of the 107 manual. |
| Weight | 136 g (5 oz), including a 3.05 m (10 ft) cable |